ADVERTISEMENT FOR BIDSCapital Projects
| Name/Description | Water or Sewer | Status | Design Year | Bid Date and results | Bid Information | awarded | Estimated Cost | Estimated Start/completion dates |
|---|---|---|---|---|---|---|---|---|
| Scout Master Lift Station Upgrade | 06-B8 Sewer |
Concept | 2010 | TBD | Advertisement Tom Puckett (513) 785-5370 |
TBD | TBD | TBD |
| LeSourdsville WRF - Expansion Phase I | 09-A6 Sewer |
In Construction | 2009 | 04/07/09 |
Steve Seitz (513) 785-6370 |
Ameritcon Rapier Electric |
$3,000,000 | Summer 2009 Summer 2010 |
| LeSourdsville WRF - Expansion Phase II | 05-A4 Sewer | In-Design | 2010 | TBD | Advertisement Steve Seitz (513) 785-6370 |
TBD | TBD | TBD |
| West Chester Road Water Main - 2,400 feet of 12" water main. | Water | In Construction | 2009 | 06/30/09 |
Wayne Beyerlein (513) 785-6367 |
Culy Excavating | $418,700 | Spring 2009 Spring 2010 |
| Hamilton -Mason Rd to Yankee Rd to (Parallel I-75) - 16" water main extension from Hamilton-Mason to Yankee Rd. (project may be completed with developer project). | Water | Concept | 2010 | TBD | Advertisement Constance Kepner (513) 785-5134 |
TBD | TBD | TBD |
| LeSourdsville WRF Phase I Improvements - Demolition and Removal Contract - Demolition and removal of various adandoned and unused structures, piping and equipment. | 09-A6 |
Awarded |
2009 | 9/15/09 |
Steve Seitz (513) 785-6370 |
Homrich, Inc. | $278,300 | Fall 2009 Spring 2010 |
| Liberty Fairfield Water Pump Station Ground Storage Tank Project - Installation of one wire-wound, prestressed concrete water storage tank and appurtenances. | 07-C1 Water |
Awarded | 2009 | 9/29/09 |
Steve Seitz (513) 785-6370 |
Natgun Corp - General Rapier Electric - Electrical |
$2,900,000 | Fall 2009 Fall 2010 |
| Cherrywood Lane Water Main Replacement Project - Installation of 1,110 ft of 6" and 2,225 ft of 8" ductile iron water main and appurtenances. | 09-B1 Water |
In Construction | 2009 | 9/15/09 |
Wayne Beyerlein (513) 785-6367 |
W.G. Stang, LLC | $235,037 | Fall 2009 Spring 2010 |
| Route 42 Water Main Replacement - Installation of 962' of 6", 2,292' of 8", 235' of 10", 817' of 12", 4,531' of 16" and 158' of 20" ductile iron water main and appurtenances. | 06-B6 Water |
On hold | 2009 | TBD | Advertisement Wayne Beyerlein (513) 785-6367 |
TBD | $1,300,000 | Spring 2011 Winter 2011 |
| Tylersville Water Main Replacement - Installation of 40' of 6", 125' of 8" and 2,930' of 12" ductile iron water main and appurtenances. | 07-C3 Water |
On hold | 2009 | TBD | Advertisement Wayne Beyerlein (513) 785-6367 |
TBD | $340,000 | Fall 2010 Winter 2010 |
| Hamilton-Mason/ Morris/Dixon Ct Water Main Replacement - Installation of approximately 8,200 linear feet of 12" ductile iron water main on Hamilton-Mason and approximately 3,300 linear feet of 8" ductile iron water main along Morris Rd and Dixon Rd | 10-A4 Water |
In-Design | 2010 | TBD | Advertisement Constance Kepner (513) 785-5134 |
TBD | TBD | Spring 2010 Winter 2010 |
| Dalewood Subdivision Water Main Replacement - Installation of 5,325' of 6", 8,015' of 8" and 1,400' of 10" ductile iron water main and appurtenances. | 10-A3 | In-Design | 2010 | TBD | Advertisement Wayne Beyerlein (513) 785-6367 |
TBD | TBD | Spring 2010 Winter 2010 |